Water Quality Test / Food Sanitary Control
Handy Water Meter AQUAB AQ-202
The AQUAB series handy water quality meters are easy-to-operate water quality photometers. As the concentration conversion curves are pre-programmed, measurements can be performed immediately after zero-point adjustment using sample water. Two-point calibration is enabled by setting to user calibration mode. Up to 99 measurement values can be stored in memory.
■ Main Functions
● Memory function
Measurement values are automatically saved up to 99 points.
In memory check mode, you can check the measurement value immediately.
● Turning the power OFF automatically or manually
The power can be automatically turned OFF even if you forget to turn it OFF. You can also turn the power OFF manually.
● For measuring high-concentration residual chlorine
Sterile water such as a sodium hypochlorite solution and hypochlorous acid water (acidic electrolyzed water, etc.) are used in wide fields such as hygienic control of various types of foods including eggs and vegetables, towels and other items in hairdressing salons and barbers, and medical equipment as well as for the prevention of infection with diseases. To maintain a sufficient antiseptic effect, you must confirm that the residual chlorine concentration is surely maintained at a certain level. The DPD method, usually used as the method to measure residual chlorine concentration, has a characteristic that it cannot measure high-concentration residual chlorine.
The AQ-202 uses the iodine method and can measure high-concentration total residual chlorine up to 300 mg/L.
■ Main Functions
● Memory function
Measurement values are automatically saved up to 99 points.
In memory check mode, you can check the measurement value immediately.
● Turning the power OFF automatically or manually
The power can be automatically turned OFF even if you forget to turn it OFF. You can also turn the power OFF manually.
● For measuring high-concentration residual chlorine
Sterile water such as a sodium hypochlorite solution and hypochlorous acid water (acidic electrolyzed water, etc.) are used in wide fields such as hygienic control of various types of foods including eggs and vegetables, towels and other items in hairdressing salons and barbers, and medical equipment as well as for the prevention of infection with diseases. To maintain a sufficient antiseptic effect, you must confirm that the residual chlorine concentration is surely maintained at a certain level. The DPD method, usually used as the method to measure residual chlorine concentration, has a characteristic that it cannot measure high-concentration residual chlorine.
The AQ-202 uses the iodine method and can measure high-concentration total residual chlorine up to 300 mg/L.
Information by Item Code (Specifications)
Item Code | 080560-202 | |
---|---|---|
Model | AQ-202 | |
Measurement Principle | Absorptiometry by Lodine reagent | |
Measurement Range | 0~300mg/L | |
Light Source | LED | |
Resolution | 1mg/L / ±1mg/L | |
Measurement Item | Residual chlorine (High concentration) | |
Measurement Method | Permeation absorption measurement | |
Measurement Wavelength | 511±2nm | |
Measuring Cell | Vial bottle with 24mm cap | |
Display Format | Digital Numbers | |
Data Recording | 99points | |
Sample Water Volume | 10mL | |
Automatic Power off | Automatic power off after 120 seconds of key operation (manual operation is also possible) | |
Light Receiving Section | Photodiode | |
Measurement Time | Approx.2 seconds for both zero-point recognition and consentration measurement | |
Power Supply | AAA batteries 4 | |
Dimensions/Weight | 70(W)x142(D)x63(H)mm - Approx. 250g | |
Accessories | Powder reagents 25 packs Sample cells 2 pieces AAA alkaline batteries 4 pieces Carrying case Quick manual |
|
Price (excluding tax) | Contact us | |
Note |
Options and Spare Parts
Powder Reagent / high residual chlorine / 100 pks
AQUAB Test Tube / 10 mL / glassware
Check Tube for AQ-202/AQ-202P