Chemical Plant Equipments
Continuous Alder Show type distillation device HO -C -500 type
The tower model uses a organ-show-type distillation tower so that it is easy to calculate the step efficiency, and the combination can provide a fu-doro on any step.
This device is designed assuming distillation of organic samples. Please contact us if you use a water sample.
● Suitable for pilot plants.
You can implement a sample and determine the amount of processing and the number of steps before the plan to build a plant.
● There is little change in step efficiency.
The distillation tower is an organ-show type, so it is easy to calculate the step efficiency, and even if the processing volume is changed, the step efficiency does not change much.
● There is little horle-up
Because the stable time is shorter than the filling type, the processing time is short.
● The liquid surface of the sample in the flask can be adjusted arbitrarily.
By controlling the liquid surface, the sample in the flask is kept constant. In addition, the liquid surface can be variable even during driving.
● You can change the device.
Because it is compatible, you can change the distillation tower and move the fu-doro.
● Glass
You can see the inside because you can see the inside. In addition, it is excellent in corrosion resistance and heat retention.
● Ha-ta-control
All hesa-ta-ta-tae is controlled.
Fruscoho-△ PIC control (ON-OFF control)
TIC control (continuous output /PID control)
You can switch.
Calam Hi-TIC control (ON-OFF control)
* The temperature range of the above used is the temperature inside the distillation flask. Note) We do not use any "mercury manmonome-ta" that used to be used for pressure control and pressure measurement of distillation devices. We adopt a "industrial instrument" without mercury.
Information by Item Code (Specifications)
Item Code | --- | |
---|---|---|
Use | Continuous processing, plant design materials | |
theoretical plate number | 50 steps, 70-80% step efficiency | |
Hold up | Approximately 70 ml | |
throughput | Max. Approximately 3.1 L/H (N-Heptan) | |
Number of preparations | 300-700 ml | |
drop in pressure | 5.32 kpa, 60%operation benzene | |
Distillation column | Orda-Show type, φ32mm, Vacuum cloak, 10 steps of 10 steps, 2 5 steps |
|
Heating mantle | Revoyer-650W for distillation tower 500W | |
Reflux ratio timer | Sample collection 0 to 999 seconds Return style 0-999 seconds |
|
Feed port | Can be moved to the tower connection part (with a f-dedicated comprehension) | |
Reboiler | Mantle-ta-ta-heated, with liquid surface control organs, capacity 1 L | |
Feed liquid | It will be decided by the specification meeting. | |
Temperature recorder | 180mm width, 6 RBIs, 0 to 300 ° C | |
pressure range | FULL VACUUM -Regular pressure | |
Operating Environment | Room temperature ~ 300 ° C | |
Power Supply | AC100V about 6KVA | |
Size | Main body 1300 (W) x 800 (d) x 4000 (H) mm Operation board 750 (W) x 440 (D) x 1850 (H) mm |
|
Price (excluding tax) | Contact us | |