Glassware

Ubbelohde Viscometer

Viscometers, Ubbelohde, calibrated certificate, borosilicate glass, ASTM, JIS

Information by Item Code (Specifications)

Product photo
Item Code 026130-0001
Viscometer constants (approximate values) 0.001
Kinematic viscosity measurement range 0.3 to 1
Price (excluding tax) Contact us
Note

Product photo
Item Code 026130-0003
Viscometer No. 0c
Viscometer constants (approximate values) 0.003
Kinematic viscosity measurement range 0.6-3
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-0005
Viscometer No. 0B
Viscometer constants (approximate values) 0.005
Kinematic viscosity measurement range 1 to 5
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-001
Viscometer No. 1
Viscometer constants (approximate values) 0.01
Kinematic viscosity measurement range 2 to 10
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-003
Viscometer No. 1c
Viscometer constants (approximate values) 0.03
Kinematic viscosity measurement range 6月30日
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-005
Viscometer No. 1b
Viscometer constants (approximate values) 0.05
Kinematic viscosity measurement range 10-50
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-01
Viscometer No. 2
Viscometer constants (approximate values) 0.1
Kinematic viscosity measurement range 20-100
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-03
Viscometer No. 2c
Viscometer constants (approximate values) 0.3
Kinematic viscosity measurement range 60-300
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-05
Viscometer No. 2B
Viscometer constants (approximate values) 0.5
Kinematic viscosity measurement range 100-500
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-1
Viscometer No. 3
Viscometer constants (approximate values) 1
Kinematic viscosity measurement range 200-1000
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-3
Viscometer No. 3c
Viscometer constants (approximate values) 3
Kinematic viscosity measurement range 600-3000
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-5
Viscometer No. 3B
Viscometer constants (approximate values) 5
Kinematic viscosity measurement range 1000-5000
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-10
Viscometer No. 4
Viscometer constants (approximate values) 10
Kinematic viscosity measurement range 2000-10000
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Item Code 026130-30
Viscometer No. 4c
Viscometer constants (approximate values) 30
Kinematic viscosity measurement range 6000-30000
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-50
Viscometer No. 4B
Viscometer constants (approximate values) 50
Kinematic viscosity measurement range 10000-50000
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.

Product photo
Item Code 026130-100
Viscometer No. 5
Viscometer constants (approximate values) 100
Kinematic viscosity measurement range 20000-100000
Price (excluding tax) Contact us
Note ・ In the viscosometer of the appropriate amount, the sample in the time of the ball C (the amount between the mark M1 and the M2) is measured and the time to leak the capillary tube, and seeks the viscosity. ・ It is a standard dynameter that does not require correction of surface tension difference. ・ There are 16 types so that motion viscosity is 0.3 to 100000mm2/s {CST centimbouts}. (With constant indicator) ・ Because the liquid pillar difference is always kept constant, accuracy is higher than SO and SF.
 